SCSUMICHIRALOnline
Loading IST...
Chiral HPLC Columns for Optical Isomer Separation

SUMICHIRAL OA Columns

SUMICHIRAL Online helps laboratories choose the right SUMICHIRAL OA phase for enantiomeric separation, optical purity testing and chiral method development. The site provides phase descriptions, searchable specifications, USP listing guidance and India quotation support from Akira Analytical Solutions Pvt. Ltd.

ManufacturerSumika Chemical Analysis Service, Ltd.

2-1, Kitasode, Sodegaura-shi, Chiba 299-0295, Japan

SUMICHIRAL OA optical isomer separation columns, Japan
India SupplierAkira Analytical Solutions Pvt. Ltd.

MIG-1 Plot No: 02, 9th Phase, KPHB Colony, Kukatpally, Hyderabad – 500085, Telangana, India

Email: sales@akiralabs.com | Tel: +91-9391852431
Browse ColumnsRequest Quote
SUMICHIRAL OA-2000 • OA-2500 • OA-3100 • OA-3200 • OA-3300 • OA-4000 • OA-4400 • OA-4600 • OA-5000 • OA-6000 • OA-7000 • OA-7700 • OA-8000 •

What this site provides

Phase Selection

Detailed customer-facing descriptions help match analyte class, mobile-phase mode and separation objective with the most relevant SUMICHIRAL phase family.

Searchable Specs

All standard analytical dimensions from the supplied distributor price list are shown without pricing. Tables can be searched by phase, I.D., length and use.

USP & AEO Content

The USP listing page and FAQ sections are written for customers and AI answer engines, with structured data for search engines and answer engines.

SUMICHIRAL Phase Families

Improved Pirkle / Amide Type

OA-2000 and OA-2500 series use low molecular weight chiral selectors on high-purity silica. They are often considered for aromatic esters, carboxylic acids, alcohols, ketones, profen-type drugs and related compounds.

Urea Type

OA-3100, OA-3200, OA-3300 and OA-4000 family phases expand selectivity for carboxylic acids, amino-acid derivatives, amines, amides, amino alcohols, esters and phosphamides. Several related phases can help reverse elution order.

Ligand Exchange Type

OA-5000, OA-6000 and OA-6100 series use copper-ion ligand exchange mechanisms and are useful for amino acids, hydroxy acids, amino alcohols and amines.

Host-Guest Type

OA-7000, OA-7700 and OA-8000 provide cyclodextrin or crown ether selectivity for aromatic compounds, amines, primary amines and ammonium-type compounds.

All Phases

OA-2000

Amide type Improved Pirkle phase

Normal phase

OA-2000I

Ion-bonded amide type

Normal phase

OA-2000S

Opposite elution-order amide type

Normal phase

OA-2000SI

Opposite elution-order ion-bonded amide type

Normal phase

OA-2500

Amide type for acids

Reversed phase / non-aqueous reversed phase

OA-2500I

Ion-bonded amide type for normal phase

Normal phase

OA-2500S

Opposite elution-order amide type for acids

Reversed phase / non-aqueous reversed phase

OA-2500SI

Opposite elution-order ion-bonded amide type

Normal phase

OA-3100

Urea type chiral phase

Normal phase and polar ionic reversed phase

OA-3100R

Opposite elution-order urea type

Normal phase and polar ionic reversed phase

OA-3200

Urea type chiral phase

Normal phase and polar ionic reversed phase

OA-3200R

Opposite elution-order urea type

Normal phase and polar ionic reversed phase

OA-3300

Urea type for profen and amino acid derivatives

Normal phase and polar ionic reversed phase

OA-3300S

Opposite elution-order urea type

Normal phase and polar ionic reversed phase

OA-4000

Urea type for normal phase and SFC

Normal phase; SFC compatible

OA-4000R

Opposite elution-order urea type

Normal phase; SFC compatible

OA-4100

Urea type for aromatic amines/amides

Normal phase; SFC compatible

OA-4100R

Opposite elution-order urea type

Normal phase; SFC compatible

OA-4400

Proline/NEA urea type

Normal phase; SFC compatible

OA-4400R

Opposite elution-order proline/NEA phase

Normal phase; SFC compatible

OA-4500

Proline/NEA urea type

Normal phase; SFC compatible

OA-4500R

Opposite elution-order proline/NEA phase

Normal phase; SFC compatible

OA-4600

tert-Leucine/NEA urea type

Normal phase; SFC compatible

OA-4600R

Opposite elution-order tert-Leucine/NEA phase

Normal phase; SFC compatible

OA-4700

tert-Leucine/NEA urea type

Normal phase; SFC compatible

OA-4700R

Opposite elution-order tert-Leucine/NEA phase

Normal phase; SFC compatible

OA-4800

Indoline carboxylic acid/NEA urea type

Normal phase; SFC compatible

OA-4900

Indoline carboxylic acid/NEA urea type

Normal phase; SFC compatible

OA-5000

Ligand exchange chiral phase

Reversed phase with copper ion mobile phases

OA-5000L

Opposite elution-order ligand exchange phase

Reversed phase with copper ion mobile phases

OA-6000

Ligand exchange chiral phase

Reversed phase with copper ion mobile phases

OA-6000R

Opposite elution-order ligand exchange phase

Reversed phase with copper ion mobile phases

OA-6100

Ligand exchange chiral phase

Reversed phase with copper ion mobile phases

OA-6100R

Opposite elution-order ligand exchange phase

Reversed phase with copper ion mobile phases

OA-7000

Cyclodextrin host-guest phase

Reversed phase

OA-7700

Acetylated cyclodextrin host-guest phase

Reversed phase

OA-8000

Crown ether host-guest phase

Normal phase and reversed phase

Search Standard Specifications

PhaseParticle Size (µm)I.D. (mm)Length (mm)Use / Notes
OA-200054.010Guard / method screening size
OA-200054.0250Analytical size
OA-200054.6150Analytical size
OA-200054.6250High resolution analytical size
OA-2000I54.010Guard / method screening size
OA-2000I54.0250Analytical size
OA-2000I54.6150Analytical size
OA-2000I54.6250High resolution analytical size
OA-2000S54.010Guard / method screening size
OA-2000S54.0250Analytical size
OA-2000S54.6150Analytical size
OA-2000S54.6250High resolution analytical size
OA-2000SI54.010Guard / method screening size
OA-2000SI54.0250Analytical size
OA-2000SI54.6150Analytical size
OA-2000SI54.6250High resolution analytical size
OA-250054.010Guard / method screening size
OA-250054.0250Analytical size
OA-250054.6150Analytical size
OA-250054.6250High resolution analytical size
OA-2500I54.010Guard / method screening size
OA-2500I54.0250Analytical size
OA-2500I54.6150Analytical size
OA-2500I54.6250High resolution analytical size
OA-2500S54.010Guard / method screening size
OA-2500S54.0250Analytical size
OA-2500S54.6150Analytical size
OA-2500S54.6250High resolution analytical size
OA-2500SI54.010Guard / method screening size
OA-2500SI54.0250Analytical size
OA-2500SI54.6150Analytical size
OA-2500SI54.6250High resolution analytical size
OA-310054.010Guard / method screening size
OA-310054.0250Analytical size
OA-310054.6150Analytical size
OA-310054.6250High resolution analytical size
OA-3100R54.010Guard / method screening size
OA-3100R54.0250Analytical size
OA-3100R54.6150Analytical size
OA-3100R54.6250High resolution analytical size
OA-320054.010Guard / method screening size
OA-320054.0250Analytical size
OA-320054.6150Analytical size
OA-320054.6250High resolution analytical size
OA-3200R54.010Guard / method screening size
OA-3200R54.0250Analytical size
OA-3200R54.6150Analytical size
OA-3200R54.6250High resolution analytical size
OA-330054.010Guard / method screening size
OA-330054.0250Analytical size
OA-330054.6150Analytical size
OA-330054.6250High resolution analytical size
OA-3300S54.010Guard / method screening size
OA-3300S54.0250Analytical size
OA-3300S54.6150Analytical size
OA-3300S54.6250High resolution analytical size
OA-400054.010Guard / method screening size
OA-400054.0250Analytical size
OA-400054.6150Analytical size
OA-400054.6250High resolution analytical size
OA-4000R54.010Guard / method screening size
OA-4000R54.0250Analytical size
OA-4000R54.6150Analytical size
OA-4000R54.6250High resolution analytical size
OA-410054.010Guard / method screening size
OA-410054.0250Analytical size
OA-410054.6150Analytical size
OA-410054.6250High resolution analytical size
OA-4100R54.010Guard / method screening size
OA-4100R54.0250Analytical size
OA-4100R54.6150Analytical size
OA-4100R54.6250High resolution analytical size
OA-440054.010Guard / method screening size
OA-440054.0250Analytical size
OA-440054.6150Analytical size
OA-440054.6250High resolution analytical size
OA-4400R54.010Guard / method screening size
OA-4400R54.0250Analytical size
OA-4400R54.6150Analytical size
OA-4400R54.6250High resolution analytical size
OA-450054.010Guard / method screening size
OA-450054.0250Analytical size
OA-450054.6150Analytical size
OA-450054.6250High resolution analytical size
OA-4500R54.010Guard / method screening size
OA-4500R54.0250Analytical size
OA-4500R54.6150Analytical size
OA-4500R54.6250High resolution analytical size
OA-460054.010Guard / method screening size
OA-460054.0250Analytical size
OA-460054.6150Analytical size
OA-460054.6250High resolution analytical size
OA-4600R54.010Guard / method screening size
OA-4600R54.0250Analytical size
OA-4600R54.6150Analytical size
OA-4600R54.6250High resolution analytical size
OA-470054.010Guard / method screening size
OA-470054.0250Analytical size
OA-470054.6150Analytical size
OA-470054.6250High resolution analytical size
OA-4700R54.010Guard / method screening size
OA-4700R54.0250Analytical size
OA-4700R54.6150Analytical size
OA-4700R54.6250High resolution analytical size
OA-480054.010Guard / method screening size
OA-480054.0250Analytical size
OA-480054.6150Analytical size
OA-480054.6250High resolution analytical size
OA-490054.010Guard / method screening size
OA-490054.0250Analytical size
OA-490054.6150Analytical size
OA-490054.6250High resolution analytical size
OA-500054.010Guard / method screening size
OA-500054.650Short analytical size
OA-500054.6150Analytical size
OA-500054.6250High resolution analytical size
OA-5000L54.010Guard / method screening size
OA-5000L54.650Short analytical size
OA-5000L54.6150Analytical size
OA-5000L54.6250High resolution analytical size
OA-600054.010Guard / method screening size
OA-600054.650Short analytical size
OA-600054.6150Analytical size
OA-600054.6250High resolution analytical size
OA-6000R54.010Guard / method screening size
OA-6000R54.650Short analytical size
OA-6000R54.6150Analytical size
OA-6000R54.6250High resolution analytical size
OA-610054.010Guard / method screening size
OA-610054.650Short analytical size
OA-610054.6150Analytical size
OA-610054.6250High resolution analytical size
OA-6100R54.010Guard / method screening size
OA-6100R54.650Short analytical size
OA-6100R54.6150Analytical size
OA-6100R54.6250High resolution analytical size
OA-700052.0150Narrow-bore analytical
OA-700052.0250Narrow-bore high resolution
OA-700054.010Guard / method screening size
OA-700054.6150Analytical size
OA-700054.6250High resolution analytical size
OA-770052.0150Narrow-bore analytical
OA-770052.0250Narrow-bore high resolution
OA-770054.010Guard / method screening size
OA-770054.6150Analytical size
OA-770054.6250High resolution analytical size
OA-800052.0150Narrow-bore analytical
OA-800052.0250Narrow-bore high resolution
OA-800054.010Guard / method screening size
OA-800054.6150Analytical size
OA-800054.6250High resolution analytical size

Frequently Asked Questions

What are SUMICHIRAL OA columns used for?

SUMICHIRAL OA columns are used for direct HPLC separation of optical isomers and for checking enantiomeric purity in pharmaceutical, agrochemical, fragrance, biochemical and quality-control laboratories.

Which SUMICHIRAL column should I start with?

Selection depends on the analyte functional group and method mode. OA-2500 and OA-3300 are common starting points for acidic compounds and profen-type drugs, OA-4000 series is useful for normal phase amines and amides, OA-5000 to OA-6100 are ligand-exchange choices for amino acids and related compounds, and OA-7000/7700 are cyclodextrin phases for aromatic and host-guest separations.

Are prices shown on the website?

No. The website provides product information, phase guidance, specifications and inquiry forms. Current quotation, delivery and availability can be requested from Akira Analytical Solutions Pvt. Ltd.

Can Akira supply SUMICHIRAL columns in India?

Yes. The site presents SUMICHIRAL columns for customers in India through Akira Analytical Solutions Pvt. Ltd. for quotation and technical coordination.

Why do some SUMICHIRAL phases have R, S, L or I versions?

Related versions can provide different selector chemistry, ion-bonding behavior or inverse elution order. This helps analysts confirm peak identity, improve impurity detection and choose the most suitable elution sequence.

Are guard columns available?

The 4.0 mm I.D. × 10 mm formats listed in the specification tables are presented as guard or method-screening sizes. Customers can request compatibility guidance for guard protection and filters.

Are SUMICHIRAL columns suitable for LC-MS?

Certain SUMICHIRAL OA phases can be used with LC-MS-friendly non-aqueous ammonium acetate/methanol conditions. LC-MS suitability depends on the phase, analyte and mobile phase.

Are SUMICHIRAL columns suitable for SFC?

Some normal-phase SUMICHIRAL OA series, especially the OA-2000 and OA-4000 families, are presented as suitable for SFC method development when compatible conditions are used.

What information should be sent for a quotation?

Send the required phase, column dimension, quantity, application or compound class, delivery location and any method requirements. Akira can then respond with quotation and availability.

Can special sizes be requested?

Products not shown in standard tables may be treated as special order items. Customers can submit the desired dimensions and phase for confirmation.